Advanced Control Module 200-500V AC/DC for 3 Poles TeSys G400/500 - LX1G3SLSEA
DESCRIPTION
| Range: | TeSys |
|---|---|
| Product or equipment type: | Contactor coil |
| Device name: | LX1G |
| Pole description: | 4P |
| Range compatibility: | TeSys G LX1G contactor coil |
| Product compatibility: | LC1G400...500 |
| [Uc] control circuit voltage: | 200...500 V AC/DC 2 phases |
| Operating time: | 20?35 ms opening, 40...55 ms closing |
| Mechanical lifespan: | 5 Mcycles |
| Max control speed: | 600 cycles/min at 60 °C |
| Coil technology: | Integrated bidirectional peak limitation |
| Control circuit voltage range: | Operational |
| Level loss: | 0...0.45 Uc (at 60 °C) |
| Wiring mode: | |
| Control circuit: | push-in connection 1 wire(s) 0.2?2.5 mm² multi-stranded rigid without end AWG 26...AWG 12 |
| Control circuit: | push-in connection 1 wire(s) 0.25?2.5 mm² flexible with end AWG 24?AWG 14 |
| Control circuit: | push-in connection 2 wire(s) 0.5?1.0 mm² rigid or semi-rigid with end AWG 20 to AWG 18 |
| Inrush power in VA: | 400 VA at 480 V DC, 60 Hz |
| Inrush power in W: | 260.0 W DC |
| Average holding power in VA: | 14.9 VA at 480 V DC, 60 Hz |
| Average holding power in W: | 4.8 W for DC network |
| Protection degree IP: | IP20 in accordance with CEI 60529 |
|---|---|
| Operating altitude: | 3000 m without derating, 5000 m with derating factor |
| Electromagnetic compatibility: | EMC immunity according to CEI 60947-4-1, Emission tests criterion A according to CEI 60947-4-1 |
| Immunity against radiated radio-electrical interference: | Test level |
| Immunity test for voltage dips and interruptions: | In accordance with SEMI F47 |
| Standards: | EN/CEI 60947-4-1, UL 60947-4-1A, CSA C22.2 No 60947-4-1 |
| Pollution degree: | 3 in accordance with CEI 60947-1 |
| Ambient operating temperature: | -25?60 °C |
| Ambient storage temperature: | -60?80 °C |
| Ambient temperature around the device: | -40?70 °C at Uc |
| Height: | 167 mm |
| Width: | 140 mm |
| Depth: | 93 mm |
| Quantity per pack: | 1 |
| Degré de protection IP: | IP2X se conformer à CEI 60536 |
|---|---|
| Altitude de fonctionnement: | 3000 m avec réduction de la tension de fonctionnement 560 V CA5000 m avec facteur de réduction |
| Compatibilité électromagnétique: | Immunité CEM conforming to CEI 60947-4-1Tests d'émission critère A conforming to CEI 60947-4-1Immunité contre les interférences radio-électriques rayonnées - test level: 2 kV conforming to EN/CEI 61000-4-3Test d'immunité aux baisses et aux interruptions de tension conforming to SEMI F47 |
| Normes: | EN/CEI 60947-4-1UL 60947-4-1ACSA C22.2 No 60947-4-1 |
| Degré de pollution: | 3 chocs dans chaque direction X, Y et Z conforme à CEI 60947-5-1 |
| Température de l'air ambiant en fonctionnement: | -25...60 °C |
| Température ambiante de stockage: | -60...80 °C |
| Température ambiante autour de l'appareil: | -40...70 °C à Uc |
| Hauteur: | 167,0 mm |
| Largeur: | 140,0 mm |
| Profondeur: | 93,0 mm |
| Quantité du lot: | 10 pièces |
| Règlement RoHS chinois: | XCommunication environnementale |
| Type d'emballage 1: | Nb produits dans l'emballage 1 |
| Code EAN: | 3606481946249 |
|---|---|
| Rappels: | Ce produit de la marque Schneider LX1G3SLSEA est de type de la gamme TeSys F. |