| Typical current consumption: |
200 mA at 24 V DC I maximum while closing with LUCM220 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD220 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD25 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD25 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD45 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD45 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD75 mA at 24 V DC I rms sealed with LUCM80 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD90 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD |
| Heat dissipation: |
3 W for control circuit with LUCA, LUCB, LUCC, LUCD1.8 W for control circuit with LUCM |
| Safety reliability level: |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Operating time: |
35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit65 ms closing with LUCM for control circuit |
| Mechanical durability: |
15 Mcycles |
| Maximum operating rate: |
3600 cyc/h |
| Product certifications: |
CEULCSACCCEACASEFAATEXMarine |
| Standards: |
EN 60947-6-2IEC 60947-6-2UL 60947-4-1, with phase barrierCSA C22.2 No 60947-4-1, with phase barrier |
| [Ui] rated insulation voltage: |
690 V conforming to IEC 60947-6-2 (pollution degree 3)600 V conforming to UL 60947-4-1600 V conforming to CSA C22.2 No 60947-4-1 |
| [Uimp] rated impulse withstand voltage: |
6 kV conforming to IEC 60947-6-2 |
| Safe separation of circuit: |
400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N |
| Fixing mode: |
Clipped (DIN rail)Screw-fixed (plate) |
| Connections - terminals: |
Power circuit: screw clamp terminals 1 cable(s) 1...10 mm² rigidPower circuit: screw clamp terminals 1 cable(s) 1...6 mm² flexible with cable endPower circuit: screw clamp terminals 1 cable(s) 2.5...10 mm² flexible without cable endPower circuit: screw clamp terminals 2 cable(s) 1...6 mm² flexible with cable endPower circuit: screw clamp terminals 2 cable(s) 1...6 mm² rigidPower circuit: screw clamp terminals 2 cable(s) 1.5...6 mm² flexible without cable endControl circuit: without connection |
| Tightening torque: |
Control circuit: 0.8...1.2 N.m flat screwdriver 5 mmControl circuit: 0.8...1.2 N.m Philips no 1 screwdriver 5 mmPower circuit: 1.9...2.5 N.m flat screwdriver 6 mmPower circuit: 1.9...2.5 N.m Philips No 2 screwdriver 6 mm |
| Width: |
45 mm |
| Height: |
154 mm |
| Depth: |
126 mm |
| Product weight: |
0.865 kg |
| Compatibility code: |
LUB |