website Skip to content
Schneider Electric SCHNEIDER Bloc différentiel Vigi NG125 80-125A Tetra 440-500V - 19049
Schneider Electric SCHNEIDER Bloc différentiel Vigi NG125 80-125A Tetra 440-500V - 19049

Bloc différentiel Vigi NG125 80-125A Tetra 440-500V - 19049

SKU : 19049

Contact us for price and lead time for this product. Our team will respond quickly.

Lead time: 2–3 weeks – Ships quickly after order confirmation
Estimated Delivery : - .

Bloc différentiel Vigi NG125 80-125A Tetra 440-500V - 19049

DESCRIPTION

Product or component type: Add-on residual current devices
Device short name: Vigi NG125
Poles description: 4P
[In] rated current: 125 A
Network type: AC
Earth-leakage sensitivity: 1000 mA3000 mA300 mA500 mA
Earth-leakage protection time delay: Adjustable instantaneous/selective/delayed
Earth-leakage protection class: Class A
Quality labels: NF
Device location in system: Outgoer
Network frequency: 50/60 Hz
[Ue] rated operational voltage: 230...415 V AC 50/60 Hz
Residual current tripping technology: Voltage independent
[Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947-2
Mounting mode: Fixed
Mounting support: 35 mm symmetrical DIN rail
Electrical connection to mcb: By screws
9 mm pitches: 11
Height: 118 mm
Width: 207 mm
Depth: 81 mm
Product weight: 0.8 kg
Connections - terminals: Tunnel type terminals rigid wire(s) 16...70 mm² maxTunnel type terminals flexible wire(s) 10...50 mm² max
Wire stripping length: 20 mm
Tightening torque: 6 N.m
Standards: IEC 60947-2
IP degree of protection: IP20 conforming to IEC 60947-2
Pollution degree: 3 conforming to IEC 60947-2
Electromagnetic compatibility: 8/20 µs impulse withstand, 5000 A conforming to IEC 60947-2
Ambient air temperature for operation: -25...60 °C
Ambient air temperature for storage: -40...85 °C
Warranty period: 18 months
Code EAN: 3303430190493
Contexte:
  • Electrically and mechanically combined to NG125 circuit-breakers
  • 30mA sensitivity: additional protection against direct contact (in accordance with IEC 364)
  • 100, 300, 500, 1000, 3000mA sensitivities: additional protection against fire and indirect contact (in accordance with IEC 364)
  • Type "si": protection of sensitive circuits (computing equipment) and those prone to disturbances (ballast lighting, power electronics)
  • Selective version S or R : tripping of the device the closest to the fault
  • Adjustable version: choice of sensitivity and tripping time by switches
  • Compliance with standards for the NG125 + Vigi NG125 module combination: IEC EN 61009 certified by national official authorities, IEC 60947-2
  • The NG125 circuit-breaker keeps the same characteristics when combined with a Vigi NG125 module


Substitution_texte: Product not available. Here is the equivalent reference that we offer: 19048 - NG125 - earth leakage add-on block - Vigi NG125 - 4P - 125A - 300mA