cam start selector switch - 1-pole - 60 °- 12 A - front mounting - red handle - K1D032RZ2
DESCRIPTION
| Range of product: | Harmony K |
|---|---|
| Product or component type: | Complete cam switch |
| Component name: | K1 |
| [Ith] conventional free air thermal current: | 12 A |
| Product mounting: | Front mounting |
| Fixing mode: | 6 screws Ø 5.2 mm |
| Cam switch head type: | With front plate 55 x 100 mm |
| Type of operator: | Red handle |
| Rotary handle padlocking: | With |
| Presentation of legend: | With metallic legend, 0 - 1 - 2 - 3 black marking |
| Cam switch function: | Start selector switch |
| Return: | Without |
| Off position: | With Off position |
| Poles description: | 1P |
| Switching positions: | Right: 0° - 60° - 120° - 180° |
| IP degree of protection: | IP40 conforming to IEC 529IP40 conforming to NF C 20-010 |
| Switching angle: | 60 ° |
|---|---|
| [Ui] rated insulation voltage: | 690 V (pollution degree 3) conforming to IEC 60947-1 |
| [Ithe] conventional enclosed thermal current: | 10 A |
| Rated operational power in W: | 10500 W AC-21, 500...660 V 3 phases conforming to IEC 60947-31100 W AC-3, 230 V 3 phases conforming to IEC 60947-31500 W AC-23A, 230 V 3 phases conforming to IEC 60947-31500 W AC-3, 400 V 1 phase conforming to IEC 60947-31500 W AC-3, 400 V 3 phases conforming to IEC 60947-31500 W AC-3, 500 V 3 phases conforming to IEC 60947-31500 W AC-3, 690 V 3 phases conforming to IEC 60947-32200 W AC-23A, 400 V 3 phases conforming to IEC 60947-32200 W AC-23A, 500 V 3 phases conforming to IEC 60947-32200 W AC-23A, 690 V 3 phases conforming to IEC 60947-34800 W AC-21, 230 V 3 phases conforming to IEC 60947-3600 W AC-3, 230 V 1 phase conforming to IEC 60947-38300 W AC-21, 400 V 3 phases conforming to IEC 60947-3 |
| [Ie] rated operational current AC: | 1 A at 500 V AC-15 conforming to IEC 60947-5-12 A at 400 V AC-15 conforming to IEC 60947-5-13 A at 230 V AC-15 conforming to IEC 60947-5-11.8 A at 690 V AC-3 3 phases conforming to IEC 60947-32.8 A at 500 V AC-3 3 phases conforming to IEC 60947-32.8 A at 690 V AC-23A 3 phases conforming to IEC 60947-33.3 A at 400 V AC-3 3 phases conforming to IEC 60947-33.8 A at 500 V AC-23A 3 phases conforming to IEC 60947-34.6 A at 230 V AC-3 3 phases conforming to IEC 60947-34.8 A at 400 V AC-23A 3 phases conforming to IEC 60947-35.6 A at 230 V AC-23A 3 phases conforming to IEC 60947-3 |
| Electrical durability: | 1000000 cycles AC-151000000 cycles AC-21500000 cycles AC-23500000 cycles AC-3 |
| Maximum operating rate: | 2.5 cyc/mn AC-212.5 cyc/mn AC-232.5 cyc/mn AC-38.333 cyc/mn AC-15 |
| Short-circuit current: | 10000 A |
| Short-circuit protection: | 16 A cartridge fuse, type gG |
| [Uimp] rated impulse withstand voltage: | 4 kV in isolating function6 kV conforming to IEC 60947-1 |
| Contact operation: | Slow-break |
| Positive opening: | With |
| Electrical connection: | Captive screw clamp terminals flexible, clamping capacity: 2 x 1.5 mm²Captive screw clamp terminals solid, clamping capacity: 1 x 2.5 mm² |
| Mechanical durability: | 1000000 cycles |
| CAD overall width: | 55 mm |
| CAD overall height: | 100 mm |
| CAD overall depth: | 63 mm |
| Product weight: | 0.17 kg |
| Compatibility code: | K1D |
| Standards: | CENELEC EN 50013EN/IEC 60947-3 for power circuitEN/IEC 60947-5-1 for control circuit |
|---|---|
| Product certifications: | CSA 240 V 1 hp 1 phaseCSA 240 V 3 hp 3 phases 2 pole(s)UL 240 V 1 hp 3 phasesUL 240 V 0.33 hp 1 phase 2 pole(s) |
| Protective treatment: | TC |
| Ambient air temperature for operation: | -25...55 °C |
| Ambient air temperature for storage: | -40...70 °C |
| Shock resistance: | 30 gn conforming to IEC 68-2-27 |
| Vibration resistance: | 5 gn (f= 10...150 Hz) conforming to IEC 68-2-6 |
| Electrical shock protection class: | Class II conforming to IEC 536Class II conforming to NF C 20-030 |
| REACh Regulation: | Free of Substances of Very High Concern above the thresholdREACh free of SVHC |
| Code EAN: | 3389110725261 |
|---|