DESCRIPTION

Range: ComPacT
Range of product: ComPact NSX400...630
Device short name: ComPacT NSX400K
Product or component type: Circuit breaker
Device application: Special application
Poles description: 3P
Protected poles description: 3t
[In] rated current: 250 A at 40 °C
[Ue] rated operational voltage: 800...1000 V AC 50/60 Hz
Network type: AC
Network frequency: 50/60 Hz
Suitability for isolation: Yes conforming to EN/IEC 60947-2
Utilisation category: Category A
Breaking capacity: 36 kA Icu at 800 V AC 50/60 Hz conforming to IEC 60947-210 kA Icu at 1000 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity code: K 10 kA 1000 V AC
Trip unit name: Micrologic 2.3
Trip unit technology: Electronic
Trip unit protection functions: LSoI
Control type: Toggle
Mounting mode: Fixed
[Ui] rated insulation voltage: 1000 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage: 8 kV
[Ics] rated service breaking capacity: 10 kA at 800 V AC 50/60 Hz conforming to IEC 60947-210 kA at 1000 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability: 15000 cycles
Electrical durability: 1000 cycles at 1000 V In
Mounting support: Backplate
Upside connection: Front
Downside connection: Front
Connection pitch: 45 mm
Protection type: L
Trip unit rating: 250 A at 40 °C
Long time pick-up adjustment type Ir: Adjustable 9 settings
Long time pick-up adjustment range: 70...250 A
Long time delay adjustment type: Fixed
[tr] long-time delay adjustment range: 11 s at 7.2 x Ir16 s at 6 x Ir400 s at 1.5 x Ir
Thermal memory: 20 minutes before and after tripping
Short-time pick-up adjustment type Isd: Adjustable 9 settings
[Isd] short-time pick-up adjustment range: 1.5...10 x Ir
Short-time delay adjustment type: Fixed
Instantaneous pick-up adjustment type Ii: Fixed
Instantaneous pick-up adjustment range: 3000 A
Earth-leakage protection: Without
Zone selective interlocking ZSI: Without
Number of slots: 6 slot(s)
Local signalling: Flashing LED (green) for ready to operateLED 105 % Ir (red) for overloadLED 90 % Ir (orange) for overload
Width: 140 mm
Height: 255 mm
Depth: 110 mm
Net weight: 6.05 kg
Standards: EN/IEC 60947
Product certifications: CECCC
Overvoltage category: IV
Electrical shock protection class: Class II
Pollution degree: 3 conforming to IEC 60664-1
IP degree of protection: IP40 conforming to IEC 60529
IK degree of protection: IK07 conforming to IEC 62262
Ambient air temperature for operation: -25...70 °C
Ambient air temperature for storage: -50...85 °C
Relative humidity: 0...95 %
Operating altitude: 0...2000 m without derating2000 m...5000 m with derating
Sustainable offer status: Green Premium productREACh Regulation
Code EAN: 3606481004826